รายละเอียดสินค้า Fluke 1587 Insulation Test Meter Kit
Fluke 1587 Insulation Multimeter combine a digital insulation tester with a full-featured, true RMS digital multimeter in a single, compact, handheld unit, which provides maximum versatility for both troubleshooting and preventative maintenance.
Whether you work on motors, generators, cables, or switch gear, the Fluke 1587Insulation Multimeter IS ideally suited to help you with your tasks and at a cost that is far less than buying the two products.
Specifications |
Voltage DC |
Maximum Voltage: |
1000 V |
Accuracy: |
1577: ±(0.2%+2) |
|
1587: ±(0.09%+2) |
Maximum Resolution: |
0.001V |
|
Voltage AC |
Maximum Voltage: |
1000 V |
Accuracy: |
1577: ±(2%+3) |
|
1587: ±(2%+3) |
AC Bandwidth: |
1587: 5kHz* |
|
*with low pass filter; 3db @ 800 Hz |
Maximum Resolution: |
0.1 mV |
|
Current DC |
Maximum Amps: |
400mA |
Amps Accuracy: |
1577: ±(1.0%+2) |
|
1587: ±(0.2%+2) |
Maximum Resolution: |
0.01 mA |
|
Current AC |
Maximum Amps: |
400mA |
Amps Accuracy: |
1577: ±(2.0%+2)* |
|
1587: ±(1.5%+2)* |
|
* 1kHz bandwidth |
Maximum Resolution: |
0.01 mA |
|
Resistance |
Maximum Resistance: |
50 MΩ |
Accuracy: |
1577: ±(1.2%+2) |
|
1587: ±(0.9%+2) |
Maximum Resolution: |
0.1Ω |
|
Capacitance(1587 only) |
Maximum Capacitance: |
9,999 µF |
Accuracy: |
±(1.2%+2) |
Maximum Resolution: |
1 nF |
|
Frequency (1587 only) |
Maximum Frequency: |
100 kHz |
Accuracy: |
±(0.1%+1) |
Maximum Resolution: |
0.01 Hz |
|
Temperature Measurement (1587 only) |
|
-40.0 °C to 537 °C |
|
-40.0 °F to 998 °F |
|
excluding probe |
|
Diode Test (1587 only) |
Range: |
6 V |
Resolution: |
1 mV |
Accuracy: |
±(2 % + 1) |
|
Insulation Test |
Minimum Test Current @ 1kΩ/V: |
|
Test Voltages: |
1577: |
500, 1000 V |
1587: |
50, 100, 250, 500, 1000 V |
|
Maximum Resistance per Test Voltage: |
50V: |
|
100V: |
|
250V: |
|
500V: |
|
1000V: |
1577: 600 MΩ |
|
1587: 2 GΩ |
|
Maximum Resolution per Test Voltage: |
50V: |
0.01 MΩ |
100V: |
0.01 MΩ |
250V: |
0.1 MΩ |
500V: |
0.1 MΩ |
1000V: |
0.1 MΩ |
|
Accuracy per Test Voltage: |
50V: |
±(3 % + 5) |
100V: |
±(3 % + 5) |
250V: |
±(1.5 % + 5) |
500V: |
1577: ±(2.0 % + 5) |
|
1587: ±(1.5 % + 5) |
1000V: |
1577: ±(2.0 % + 5) |
|
1587: ±(1.5 % + 5) to 600 MΩ, ±(10 % + 3) above 600 MΩ |
|
Environmental Specifications |
Operating temperature |
|
Storage temperature |
|
Humidity (Without Condensation) |
|
0% - 95% (10 °C – 30 °C) |
|
0% - 75% (30 °C – 40 °C) |
|
0% - 40% (40 °C – 55 °C) |
|
Operating Altitude |
|
Safety Specifications |
Overvoltage category |
|
Complies with ANSI/ISA 82.02.01 (61010-1) 2004, CAN/CSA-C22.2 NO. 61010-1-04, and IEC/EN 61010-1 2nd Edition for measurement CAT III 1000 V and CAT IV 600 V |
|
Agency Approvals |
|
2000 m CAT III 1000 V, CAT IV 600 V; 3000 m CAT II 1000 V, CAT III 600 V |
|
Mechanical & General Specifications |
Size |
|
203 x 100 x 50 mm (with holster) |
|
Weight |
|
Warranty |
|
Battery life Alkaline |
Meter use: |
1000 hours |
Insulation test use: |
Meter can perform at least 1000 insulation tests with fresh alkaline batteries at room temperature. These are standard tests of 1000 V into 1 MΩ with a duty cycle of 5 seconds on and 25 seconds off. |
|
IP Rating |
|
รีวิว (2)
Customer
10/12/2560 13:51
คุณภาพสินค้าดีมาก
Customer
10/12/2560 13:51
คุณภาพสินค้าดีมาก